Slab and road lifting
Tektrench is a pumpable two-component self-foaming product used to build pillows and breakers that support pipelines. It is also used to slow or stop the ingress of water in gas, oil, or utility pipeline trenches.
Using Tektrench reduces worker fatigue and improves safety as related to navigating confined spaces while manually handling and placing heavy sandbags.ÃÂ
Using a pumped-in-place installation method for trench pillows, breakers, and plugs improves field operational efficiency by reducing manpower requirements, lowering material usage, costs, and waste.
The following data are laboratory data. They may vary in practice due to thermal exchange between resin and strata, pressure, and other factors.
| Initial temperatureÃÂ | Start of foamingÃÂ | End of foamingÃÂ | Foaming factor | Test procedureÃÂ |
| 25 ðCà| 20 s ñ 10 sà| 45 s ñ 15 sà| 15 - 30à| MCT PV 10-303à|
| Component AÃÂ | Component BÃÂ | Norm | |
| Density at 25 ðCà| 1455 ñ 30 kg/m3à| 1220 ñ 15 kg/m3à| DIN 12791 |
| Colour | brownish-turbidÃÂ | brown | |
| Viscosity at 25 ðCà| 260 ñ 80 mPa*sà| 140 ñ 15 mPa*sà| ISO 3219à|
| Flash point | n.a. ðC | > 200 ðCà| DIN 53213 |
All forms of packing are approved to the danger goods regulation road (GGVS).ÃÂ
Component A: 19 l in a can; 24 l in a PE canisterÃÂ
Component B: 19 l in a can; 24 l in a PE canister
At least six months from date of delivery or twelve months from date of production when stored in a dry place between 10 ðC and 30 ðC. If this time is exceeded, we recommend having the material checked by Minova for compliance with specification. When the material is warmed up, local overheating, e.g. at the container wall, must be avoided by any means.